Structural EnFace OCT course
EnFace OCT evaluates structure changes differently, constructing frontal sections or C-scans in a coronal plane by possessing a 3D cube for the posterior pole using B-scan. The software will slice this cube into C-Scans for each retinal layer
In this presentation, I will talk about normal findings as OCT machines automatically produce four slabs. This presentation discusses the possible artifacts in structural OCT such as Motion, blink, projection, segmentation artifacts, and other.